Ipambuka
Lyser minangka solusi kimia khusus sing digunakake kanggo pewarna komponen seluler (umpamane, inti, sitoplasma) ing conto getih, ngidini instrumen hematologi otomatis kanggo: mbedakake jinis sel getih (WBC, RBC, trombosit), ngenali kelainan morfologis, ngitung parameter seluler. Lyser kanggo instrumen hematologi Sysmex khusus kanggo penganalisa hematologi seri Sysmex, kalebu macem-macem model saka seri analisa 5 lan 3 bagean.
Spesifikasi
- Kanggo Sysmex 5-part series:
XN seri B1/B2/B3/B4
|
Kode |
Katrangan |
Spesifikasi |
Periode Validitas |
Suhu |
|
0307004 |
STAC-LYSER-SYSSLS |
1,5Lx2botol/kotak |
24m |
2-35 derajat |
|
0307005 |
STAC-LYSER-SYSWNR |
4Lx2botol/kotak |
24m |
2-35 derajat |
|
0307006 |
STAC-LYSER-SYSWDF |
4Lx2botol/kotak |
24m |
2-35 derajat |
|
0307007 |
STAC-LYSER-SYSWPC |
1,5Lx2botol/kotak |
24m |
2-35 derajat |
|
030700401 |
STAC-LYSER-SYSSLS |
500ml x 3 botol / kothak |
24m |
2-35 derajat |
|
030700501 |
STAC-LYSER-SYSWNR |
5L/kotak |
24m |
2-35 derajat |
|
030700601 |
STAC-LYSER-SYSWDF |
5L/kotak |
24m |
2-35 derajat |
- Kanggo Sysmex 5-part series:
XT-1800i / 2000i / 4000i
|
Kode |
Katrangan |
Spesifikasi |
Periode Validitas |
Suhu |
|
030403 |
STAC-LYSER-SYS-FBA |
5L/kotak |
24m |
2-35 derajat |
|
030003 |
STAC-LYSER-SYS-SLS |
5L/kotak |
24m |
2-35 derajat |
|
030501 |
STAC -LYSER-SYS-4DL |
5L/kotak |
24m |
2-35 derajat |
|
030502 |
STAC -LYSER-SYS-4DS |
42ml x 3 unit / kothak |
24m |
2-35 derajat |
XE-2100/XE-5000
|
Kode |
Katrangan |
Spesifikasi |
Periode Validitas |
Suhu |
|
030403 |
STAC-LYSER-SYS-FBA |
5L/kotak |
24m |
2-35 derajat |
|
030003 |
STAC-LYSER-SYS-SLS |
5L/kotak |
24m |
2-35 derajat |
|
030501 |
STAC -LYSER-SYS-4DL |
5L/kotak |
24m |
2-35 derajat |
|
030502 |
STAC -LYSER-SYS-4DS |
42ml x 3 unit / kothak |
24m |
2-35 derajat |
|
030504 |
STAC-LYSER-SYS-IM |
10L/kotak |
24m |
2-35 derajat |
|
030505 |
STAC-LYSER-SYS-NR&Dye |
1L+12ml/kotak |
18m |
2-35 derajat |
XS-500i/XS800i/XS900i/XS1000i
|
Kode |
Katrangan |
Spesifikasi |
Periode Validitas |
Suhu |
|
030003 |
STAC-LYSER-SYS-SLS |
5L/kotak |
24m |
2-35 derajat |
|
030501 |
STAC -LYSER-SYS-4DL |
5L/kotak |
24m |
2-35 derajat |
|
030502 |
STAC -LYSER-SYS-4DS |
42ml x 3 unit / kothak |
24m |
2-35 derajat |
- Kanggo Sysmex 3-part series:
KX-21/KX-21N/poch-80i/poch-100i/XP-100/XP-300
|
Kode |
Katrangan |
Spesifikasi |
Periode Validitas |
Suhu |
|
030301 |
STAC-LYSER-SYS-WH |
500mlx 3botol/box |
24m |
2-35 derajat |
K-1000/K-4500
|
Kode |
Katrangan |
Spesifikasi |
Periode Validitas |
Suhu |
|
030003 |
STAC-LYSER-SYS-SLS |
5L/kotak |
24m |
2-35 derajat |
|
030201 |
STAC-LYSER-SYS-3WP |
5L/kotak |
24m |
2-35 derajat |
produkrinci
Aplikasi:Lyser kanggo instrumen hematologi Sysmex ditrapake kanggo seri bagean Sysmex 5-: XN-B1/XN-B2/XN-B3/XN-B4,XT-1800i/2000i/4000i,XE-2100/XE-5000,XS-500i/XS800i/XS900i/XS900i/XS-party seri: KX-21 / KX-21N / poch-80i / poch-100i / XP-100 / XP-300, K-1000 / K-4500 hematology analyzer line.
- Asal:Shanghai, China
- Sertifikasi:CE, ISO 13485, CNAS L18717, MSDS
- rega:Bisa nego
- Tanggal pangiriman:Bisa nego
- Packing:standar ekspor
- MOQ:1 atur
- Keuntungan biaya:Dibandhingake karo reagen pabrik asli, efektifitas biaya gedhe.
FAQ
P: Apa sing nyebabake weker "Lyser Empty" (Kode 103000)?
A: Solusi:
Ganti botol lyser sing wis entek.
Jalur reagen utama: Maintenance > Reagent Prime > Pilih Lyser.
Yen tetep, priksa keselarasan sensor botol (resik nganggo swab alkohol).
Q: Why does HGB show high blank (>0,2 g/dL)
A: Penyebab:
● Kontaminasi Lyser (contone, bledug ing muncung)
● Reagen kadaluwarsa (verifikasi kadaluwarsa batch)
● Kristalisasi ing pipa (umum ing asor<30%)
Ndandani:

P: Urip beting sawise mbukak?
A: Suhu panyimpenan: Duration maksimum
15-25 derajat: 90 dina
>30 derajat: 30 dina
Cathetan: Tulis tanggal buka ing botol!
Panas Tags: Lyser kanggo instrumen hematologi sysmex, China Lyser kanggo instrumen hematologi sysmex produsen, pemasok